Written by : Nick 04-05-2024

Optimizing BFT Kustos Double Swing Repair

Motor Limit Switch Adjustment

Today, repaired a BFT Kustos double swing gate. Here you can read about BFT drop bolt installation. Also the motor’s limit switches adjustments are crucial.

Turning the BFT Kustos motor

To adjust the operator limit switches, turn the motor around if it’s installed low.

Algorithm for Precision regarding BFT Kustos motor

Follow these steps to minimize motor turning and ensure precise positioning:

BFT Kustos Limit Switch Adjustment
  1. Connect the motor to the controller and open it to the limit switch without attaching it to the leaf.
BFT Kustos Limit Switch Adjustment

2. Mark the positions of the piston and magnet when the motor is fully open.

BFT Kustos Limit Switch Adjustment

3. Install the motor to the brackets and close it manually.

BFT Kustos Limit Switch Adjustment

4. Flip the motor, mark the piston’s end again, and measure the new position.

BFT Kustos Limit Switch Adjustment

5. Move the magnetic reader to the same distance.

Now, the motor should stop in the right place.

Conclusion

By following this algorithm, you can optimize your double swing gate repair for accurate motor positioning and efficient operation.

BFT Kustos Limit Switch Adjustment

Diagnosing and fixing unique technical issues within the gate industry.

Contact us today for any consultation
regarding gates. We help you diagnose the problem
and figure out the best possible solution.